Configuratii standard & Optionale
| eComfort Therma 220 - 500 KW | | REFRIGERANT CIRCUIT | R32 | Standard | | R1234ze | | | R513a | | | R134a | | | Winter cooling operation | Optional | | Low leaving water temperature down to -10°C | Optional | | | | SAFETY PACK | Refrigerant leak detection + PRV + acoustic and visual alarms | | | | | COMPRESSOR | Multiscroll | Standard | | Screw | | | Inverter | Optional | | Low noise | Optional | | Super low noise | Optional | | | | EXPANSION VALVE | Thermostatic | | | Electronic | Standard | | | | FAN | AC fan | | | Variable air flow control of condensation : HP floating | Standard | | EC Fan | Standard | | Fan static pressure | | | | | AIR COIL | Standard copper tube/aluminium fin (1) | Standard | | Micro channel heat exchanger (2) | | | Heavy anti-corrosion coil treatment | Optional | | Coils protection guards | Optional | | | | HEAT EXCHANGER | Brazed plate heat exchanger | Standard | | Shell and Tube | | | | | ELECTRICAL | Main disconnect switch | Standard | | Phase reversal protection | Optional | | Antifreeze protection | Optional | | Softstarter | Optional | | Water tank modulating electrical heater (Heat pump) | Optional | | Power factor correction | Optional | | Energy metter | Optional | | | | HYDRAULIC MODULE | Paddle flow switch | Standard | | Electronic flow switch | | | Water filter | Optional | | Flange connection | Optional | | Water tank | Optional | | Low-pressure single pump | Optional | | Low-pressure twin pump | Optional | | High-pressure single pump | Optional | | High-pressure twin pump | Optional | | eDrive high-pressure single pump (variable primary flow) | Optional | | eDrive high-pressure twin pump (variable primary flow) | Optional | | By-pass valve for Delta P control (eDrive) | Optional | | | | CONTROL AND COMMUNICATION | Modbus RS485 communication interface | Optional | | BACnet MSTP communication interface | Optional | | Modbus/BACnet/Ethernet TCP/IP communication interface | Optional | | Basic display | na | | Advanced display | Standard | | Service display | Optional | | Remote confort display | Optional | | Extension board for aditional input/output | Optional | | Distance Management System: RedgeCloud connectivuty | Optional | | Distance Management System: RedgeOneWeb | Optional | | | | ENERGY SAVING | Partial heat recovery | Optional | | Total heat recovery | | | Free-cooling | | | | | MISCELLANEOUS | Rubber anti-vibration mounts | Optional | | Spring antivibrations mounts | |
Avantaje
- Instalare si comisionare facile datorita integrarii modulului hidraulic complet cu rezervor.
- Optimizat pentru incalzire, chiar si pentru cele mai reci sezoane.
- Eficiente SCOP ridicate, depasind cerintele EcoDesign 2017 pentru aplicatii de incalzire.
- Control precis al termperaturii apei in modul de incalzire si cel de racire multumita componentelor cu eficienta ridicata.
Sistemul termodinamic
- Compresoare multi-scroll, montate in tandem sau trio, pentru furnizarea celor mai bune eficiente.
- Schimbatoare de caldura cu suprafata mare, construite din tevi de cupru si aripioare din aluminiu.
- Ventilatoare de performanta cu palele profilate pentru eficienta ridicata si nivel redus de zgomot.
- Schimbatorul de caldura cu apa este izolat termic si protejat la inghet si este cosntruit din placi din inox, brazat in cupru.
- Unul sau doua circuite independente, fiecare echipat cu valva de expansiune electronica.
- Desuperheater (optional) : schimbator de caldura suplimentar cu placi pe fiecare circuit pentru a recupera caldura rejectata și a furniza apa calda gratuita in scopuri sanitare sau industriale.
eDrive
Pompa cu viteza variabila, care moduleaza debitul de apa prin schimbatorul de caldura reduce costurile energiei consnumate: - Economiseste consumul de energie in special la sarcina partiala si in perioadele de repaus, ajungand la o reducere de pana la 75% a consumului pompei.
- Economii in sistemul initial, datorita unui numar mai mic de pompe si racorduri decat in cazul sistemelor primar-secundar.
- Flexibilitate si precizie a controlului functionarii pompei: pornire si oprire lina, schimbare graduala a vitezei, precizie si stabilitate a controlului.
- Reducerea solicitarii repetate asupra pompei si conductelor, rezultand o durata de viata mai lunga a echipamentului.
- Eliminarea curentului de pornire datorita acționarii cu frecvența variabila care controleaza alimentarea graduala a motorului pompei.
Control
- Controler electronic eClimatic și parametri de control inteligent care optimizeaza eficienta la sarcina partiala.
- Solutii de comunicatie integrate care ofera flexibilitate (master/slave, Modbus).
- Afișaj DC Advanced, echipat cu un ecran grafic care ofera acces la principalii parametri ai utilizatorului, cu doua afișaje optionale:
- -Afisaj la distanța
- -Afisaj de service
eCLIMATIC
DC Advanced
Carcasa si aspect
- Carcasa din otel galvanizat vopsit in alb.
- Design compact, posibil prin instalarea schimbatoarelor cu dispunere in V.
- Toate componentele termodinamice si hidraulice sunt instalare sub schimbatoare.
Confort acustic
Trei configuratii diferite ale nivelului de zgomot disponibile: - Funcționare silențtoasa (standard), obtinuta prin design compact, compresoare si pompe silentioase si cu ventilatoare cu elice de inalta performanța, toate instalate într-o incinta închisa.
- Optiune de nivel redus de zgomot: izolatia acustica a compresorului de înalta performanta poate prelua zgomotul produs de unitate.
- Sistemul activ de atenuare acustica cu viteza variabilă a ventilatorului permite adaptarea progresiva a unitatii la sarcina cladirii respectand in acelasi timp constrangerile privind nivelul de zgomot si limitele de functionare (optional).
Monitorizare la distanta
- Conectivitate prin RedgeCloud
- BMS prin: e-savvy
e-savvy
Touch panel
Pompa de caldura - air source
|
|
| Heating capacity (1) | kW | 217,0 | 251,8 | 272,9 | 313,8 | 354,3 | | Total absorbed power (1) | kW | 69,7 | 82,8 | 90,0 | 99,3 | 118,1 | | COP (1) | 3,11 | 3,04 | 3,03 | 3,16 | 3,00 | | Comfort | Standard Fans | Seasonal Coeficient of Performance (6) | 3.875 | 3.85 | 3.8 | 3.9 | 3.875 | | Application | SCOP | | | Seasonal energy efficiency (7) | % | 152 | 151 | 149 | 153 | 152 | | | s,h | |
| Cooling capacity (1) | kW | 201,0 | 237,7 | 255,7 | 287,7 | 328,0 | | Total absorbed power (1) | kW | 74,2 | 86,9 | 97,1 | 105,0 | 119,9 | | EER (1) | 2,71 | 2,74 | 2,63 | 2,74 | 2,74 | | Comfort | Standard Fans | Seasonal Energy Efficiency Ratio (2) | 4.625 | 4.3 | 4.225 | 4.475 | 4.4 | | Application | SEER | | | Seasonal energy efficiency (3) | % | 182 | 169 | 166 | 176 | 173 | | | s,c | | | | | | | Process Application | Seasonal Energy Performance Ratio (4) | 6.12 | 6.07 | 5.84 | 6.36 | 6.05 | | SEPR - High temperature (7°C) | | | | | | | Seasonal Energy Performance Ratio (5) | 3.76 | 3.78 | 3.72 | 3.82 | 3.76 | | SEPR - Medium temperature (-8°C) | |
| Global sound power level - Standard unit | dB(A) | 91,1 | 93,0 | 93,0 | 92,4 | 94,5 | | Sound power level - Standard unit + LNCJ option + QUIET setting | dB(A) | 90,6 | 92,3 | 92,3 | 92,1 | 94,6 | | Heating capacity HM2 40/45°C LNCJ option + QUIET setting | kW | 204,0 | 238,0 | 257,0 | 295,0 | 334,0 | |
| Maximum power | kW | 95.6 | 111.9 | 122.3 | 134.6 | 158.1 | | Maximum current | A | 158.9 | 181.4 | 198.9 | 218.4 | 257.2 | | Starting current | A | 323.6 | 332 | 380.8 | 369 | 439.1 | | Short circuit current | kA | 50,0 | 50,0 | 50,0 | 50,0 | 50,0 | |
| Number of circuits | 2 | 2 | 2 | 2 | 2 | | Number of compressors | scroll/2+2 | scroll/2+2 | scroll/2+2 | scroll/2+3 | scroll/2+3 | | Total refrigerant load - R32 | kg | 41,0 | 42,0 | 44,0 | 57,0 | 58,0 | |
| Nominal water flow rate | m³/h | 37,4 | 43,4 | 47,1 | 54,1 | 61,1 | | Nominal pressure drop | kPa | 30,8 | 29,5 | 34,4 | 45,0 | 52,5 | |
| Type | Victaulic | | Diameter | 4" |
Pompa de caldura - air source
|
|
| Heating capacity (1) | kW | 364,9 | 380,6 | 412,5 | 451,7 | 484,0 | | Total absorbed power (1) | kW | 121,7 | 125,6 | 130,9 | 149,9 | 158,3 | | COP (1) | 3,00 | 3,03 | 3,15 | 3,01 | 3,06 | | Comfort | Standard Fans | Seasonal Coeficient of Performance (6) | 3.85 | 3.85 | 4.025 | 3.8 | 3.875 | | Application | SCOP | | | Seasonal energy efficiency (7) | % | 151 | 151 | 158 | 149 | 152 | | | s,h | |
| Cooling capacity (1) | kW | 336,9 | 352,3 | 385,0 | 423,0 | 455,3 | | Total absorbed power (1) | kW | 125,0 | 130,9 | 138,1 | 152,7 | 164,4 | | EER (1) | 2,69 | 2,69 | 2,79 | 2,77 | 2,77 | | Comfort | Standard Fans | Seasonal Energy Efficiency Ratio (2) | 4.375 | 4.275 | 4.975 | 4.75 | 4.35 | | Application | SEER | | | Seasonal energy efficiency (3) | % | 172 | 168 | 196 | 187 | 171 | | | s,c | | | | | | | Process Application | Seasonal Energy Performance Ratio (4) | 5.99 | 5.82 | 6.28 | 6 | 5.94 | | SEPR - High temperature (7°C) | | | | | | | Seasonal Energy Performance Ratio (5) | 3.74 | 3.68 | 3.79 | 3.72 | 3.68 | | SEPR - Medium temperature (-8°C) | |
| Global sound power level - Standard unit | dB(A) | 94,5 | 95,8 | 94,1 | 95,6 | 97,4 | | Sound power level - Standard unit + LNCJ option + QUIET setting | dB(A) | 86,9 | 88,1 | 86,4 | 87,9 | 89,8 | | Heating capacity HM2 40/45°C LNCJ option + QUIET setting | kW | 344,0 | 359,0 | 388,0 | 426,0 | 457,0 | |
| Maximum power | kW | 163.3 | 168.4 | 180.9 | 204.4 | 214.4 | | Maximum current | A | 265.9 | 277 | 294.1 | 333 | 355.1 | | Starting current | A | 447.8 | 586.8 | 476 | 514.8 | 664.9 | | Short circuit current | kA | 50,0 | 50,0 | 50,0 | 50,0 | 50,0 | |
| Number of circuits | 2 | 2 | 2 | 2 | 2 | | Number of compressors | scroll/2+3 | scroll/2+2 | scroll/3+3 | scroll/3+3 | scroll/2+2 | | Total refrigerant load - R32 | kg | 59,0 | 60,0 | 79,0 | 80,0 | 82,0 | |
| Nominal water flow rate | m³/h | 62,9 | 65,6 | 71,2 | 77,9 | 83,5 | | Nominal pressure drop | kPa | 55,6 | 58,2 | 34,0 | 40,5 | 38,8 | |
| Type | Victaulic | | Diameter | 4" | 5" |
Dimensiuni
Pompe de caldura - air source
|
| A | | 2765 | 2765 | 2765 | | B | mm | 2264 | 2264 | 2765 | | C | | 2402 | 2264 | 2765 | |
| Basic unit | kg | 1950 | 2080 | 2090 | 2720 | 2746 | 2765 | 2796 | 3412 | 3498 | 3529 |
|